Questions for Adam
The measured zip has 42 IES files. Every file is CRI>70, 5000K (code 750), with no modification. The new documents and the new zip use the catalogue code printed inside each file.
Missing photometric files
There is no measured file for these.
- LEN-100B-750-60
- LEN-100B-750-90
- LEN-100B-750-110
- LEN-100B-750-A1
- LEN-100B-750-A2
- LEN-100B-750-A3
- LEN-150B-750-60
- LEN-150B-750-90
- LEN-150B-750-110
- LEN-150B-750-A1
- LEN-150B-750-A2
- LEN-150B-750-A3
File name differs from the code inside the file
Please confirm the code inside the file.
- LEN-200A-750-A2.IES. Code inside the file: LEN-200B-750-A2. Luminous opening 0.680 × 0.325 × 0.000 m. Input 200 W.
- LEN-240A-750-A2.IES. Code inside the file: LEN-240B-750-A2. Luminous opening 0.680 × 0.325 × 0.000 m. Input 240.05 W.
- LEN-300A-750-A2.IES. Code inside the file: LEN-300B-750-A2. Luminous opening 0.680 × 0.325 × 0.000 m. Input 297.45 W.
- LEN-400A-750-A2.IES. Code inside the file: LEN-400C-750-A2. Luminous opening 1.020 × 0.325 × 0.000 m. Input 397.88 W.
- LEN-480A-750-A2.IES. Code inside the file: LEN-480C-750-A2. Luminous opening 1.020 × 0.325 × 0.000 m. Input 482.08 W.
Modifications and lumens
A modification can change the lumen. The sheet says a modification which affects light output has its own photometric file, named with the modification on the end. The sheet does not print that lumen. No modification file is in the measured zip.
Which modifications change the light output, and what is the lumen for each?
Other CRI codes
Every measured file is code 750. Do 730, 740, 830, 840 and 850 have photometric files?