KKELLWOODLIGHTING Tel 01387 255 816Edit seriesOffice

Street · Street Light

ARBUTHNOT SERIES

Amenity Street Lights

  • 27W to 120W
  • 3,105lm to 13,200lm
  • 115lm/W
  • IP66
  • 5 Years warranty

Order code ARB-27-750-1M-D1-SE-GR

3,105 lm

CRI>70, 5000K. IESNA Type I Medium optic. GR Grey.

Measured file ARB-27-750-1M: 3,108 lm at 27 W (115.1 lm/W).

27W nominal. 480 × 480 × 521 mm, 8.7 kg (excludes bracketry). Driver Mean Well HLG-40H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.

Request a quote

Arbuthnot Series

BUILD THIS FITTING

Order code ARB-27-750-1M-D1-SE-GR

3,105 lm

CRI>70, 5000K. IESNA Type I Medium optic. GR Grey.

Measured file ARB-27-750-1M: 3,108 lm at 27 W (115.1 lm/W).

27W nominal. 480 × 480 × 521 mm, 8.7 kg (excludes bracketry). Driver Mean Well HLG-40H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.

CIBSE target · 200 lx

Lux does not change the order code.

My schedule

Request a lighting design

Modification

  • CE
  • 115 lm/W
  • 5 years
  • IK08
  • IP66
  • Dimmable

The Arbuthnot Series post-top street light is designed to enhance contemporary, architecturally-driven urban landscapes while delivering efficient, high-performance illumination.

Available in a variety of lumen outputs, colour temperatures, and optical configurations, it suits a broad range of applications.

Lower wattage and warm colour temperature models are ideal for pedestrian walkways and amenity spaces, while higher-output, cooler colour options are better suited to car parks and open areas where a modern aesthetic is desired.

Energy usage is minimised with optional Wireless Pro control for networked lighting management or traditional standalone photocell control, enabling automatic operation from dusk to dawn.

Request a quote or a lighting design. Kellwood prices the fitting. The order code goes with the request.

Order code ARB-27-750-1M-D1-SE-GR

Performance summary
Series codeARB
Nominal power27W to 120W
Efficacy115lm/W @ CRI>70, 5000K CCT, for Type 1M, 2M and 3M (Type V 120° about 13% higher)
Lumen output3,105lm to 13,200lm
Lumen maintenanceL70B50 ≥90,000 hours @ Ta 25°C (TM21 reported); TM21 calculated ≥181,000 hours (27W to 56W), ≥142,000 hours (70W to 120W)
CertificationCE, RoHS, ENEC
Warranty5 Years

Sheet lumen at CRI>70, 5000K, with no modification: 27 3,105 lm, 37 4,255 lm, 56 6,440 lm, 70 8,050 lm, 90 10,350 lm, 120 13,200 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 17 measured files give 110.1 to 130.1 lm/W; the measured figure for the chosen optic shows under the code.

DOWNLOADS

Questions for Adam list what the sheet and the measured files do not settle yet.

LIGHT DISTRIBUTION OPTIONS


120

90°60°30°0°30°60°90°
Polar

120° circular

Symmetric

Clear

Drawn from the beam setting, not measured

1M

90°60°30°0°30°60°90°
Polar
±2.75 H
Isolux

IESNA Type I Medium

Asymmetric

Clear

Measured, ARB-120-750-1M

2M

90°60°30°0°30°60°90°
Polar
±2.75 H
Isolux

IESNA Type II Medium

Asymmetric

Clear

Measured, ARB-120-750-2M

3M

90°60°30°0°30°60°90°
Polar
±2.5 H
Isolux

IESNA Type III Medium

Asymmetric

Clear

Measured, ARB-120-750-3M

Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.

DESIGN FEATURES


Post-top street lights designed for Purpose

Consideration has been given to a range of features, including: Contemporary Housing Design: A smooth housing with a modern style, ensures that the light complements architecturally-focused urban landscapes. Corrosion-resistant to Maintain Visual Appeal: The paint finish and stainless steel fixings ensure the product remains looking its best for it's entire lifetime. Quick Installation and Maintenance: Tool-less entry and auto switch disconnect promote quick installation and easy maintenance. Additional installation efficiency is provided by Zhaga Book 18 or NEMA socket. Increased longevity: integrated 10kV surge protection, IK08 impact rating, and internal uninterrupted gasket providing IP66 ingress resistance minimise maintenance requirements. Outputs, Colour Temperature and Optics for all applications: 27W - 120W, four different light distributions, and CCT (including 2700K) ensure that the Arbuthnot Series can be tailored to the individual project. Energy-Saving Controls: DALI Dimming, Wireless Pro network lighting, contols, or standard photocells are all available (with Zhaga Book 18 or NEMA interface)

Post-top street lights designed for Purpose

TYPICAL APPLICATIONS


SPECIFICATIONS


Light source
Chip Brand, Model, & SizePhilips Lumileds 3030
Chip Efficacy @ CRI>70, 5000K CCT188lm/W @ 65mA
Light EmmissionDirect
CCT5000K, (3000K, 4000K, 5700K optional)
CRI≥70
SDCM<5
DiffusersClear
Symmetric Light Distribution120°
Asymmetric Light DistributionIESNA Type 1M, 2M, 3M
Electrical
System Operating PowerARB-27: 27W; ARB-37: 37W; ARB-56: 56W; ARB-70: 70W; ARB-90: 90W; ARB-120: 120W
Driver BrandMean Well (D1, D2); Inventronics (D3)
Driver ModelARB-27 and ARB-37: HLG-40H; ARB-56: HLG-60H; ARB-70: HLG-80H; ARB-90 and ARB-120: HLG-120H (D1, D2)
System Power Factor>0.9
Typical Driver Lifetime62,000 hours
Input Voltage100-240VAC
Input Frequency50-60Hz
Qty of Drivers per Light1
Inrush Current Per Driver @ 230VAC, measured at 50% Ipeak (Peak/Duration)ARB-27 and ARB-37: 50A/210μs; ARB-56: 55A/265μs; ARB-70: 70A/485μs; ARB-90 and ARB-120: 60A/375μs
Power Factor>0.9
THD<20% (100-240VAC)
Surge Protection/Fusing10kA integrated surge protection device
Environmental
IP RatingIP66
IK RatingIK08 (IK09 body, IK08 tempered glass front face)
Ambient Usage Tolerance-40°C to 50°C
Ambient Storage Tolerance-40°C to 50°C
Ambient Humidity Tolerance10% to 90% RH
Physical/Mechanical
Product Dimensions: LxWxH (mm)480 x 480 x 521
Windage0.217m²
Qty of LED ChipsARB-27: 72; ARB-37: 96; ARB-56: 120; ARB-70: 144; ARB-90: 168; ARB-120: 168
Electrical ConnectionTerminal Block
Fixture WeightARB-27: 8.7kg; ARB-37: 8.9kg; ARB-56: 9.0kg; ARB-70: 9.1kg; ARB-90: 9.2kg; ARB-120: 9.2kg (excludes bracketry)
Fixture Primary Material(s)Aluminium Alloy
Fixture FinishPowder Coated
Lens(es) MaterialsUV stabilised polycarbonate (Type 1M, 2M, 3M); tempered glass (Type V 120°)
Dimming/Controls
Dimming Options1-10V, DALI
Built-in ControlsPhotocell
Compatible intelligent lighting systemsWireless Controls and Monitoring
Options/Accessories
Mounting StylesPost Top, Side Entry (both take a 60mm outer diameter spigot)
Available Product ColoursGrey
Each body (size and weight exclude bracketry)
2727W nominal. 480 × 480 × 521 mm, 8.7 kg (excludes bracketry). Driver Mean Well HLG-40H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.
3737W nominal. 480 × 480 × 521 mm, 8.9 kg (excludes bracketry). Driver Mean Well HLG-40H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.
5656W nominal. 480 × 480 × 521 mm, 9.0 kg (excludes bracketry). Driver Mean Well HLG-60H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.
7070W nominal. 480 × 480 × 521 mm, 9.1 kg (excludes bracketry). Driver Mean Well HLG-80H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.
9090W nominal. 480 × 480 × 521 mm, 9.2 kg (excludes bracketry). Driver Mean Well HLG-120H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.
120120W nominal. 480 × 480 × 521 mm, 9.2 kg (excludes bracketry). Driver Mean Well HLG-120H (D1, D2); Inventronics (D3). CE, RoHS, ENEC.

Efficacy is for Type 1M, 2M and 3M. Type V 120° output is about 13% higher; the lumen figures shown are for 1M, 2M and 3M.

Post top mounting slightly alters the photometry against side entry.

Electrical parameters are for D1 drivers unless otherwise stated. Fixture weights exclude bracketry; see the Packaging Weights & Dimensions data sheet for bracketry and accessory weights.

If more than one modification is required, separate each modification with a hyphen at the end of the product code.

Select a compatible driver for occupancy sensors with dimming.

Modifications which affect light output have separate photometric files identified with +(modification).

Alternative drivers may be available. Contact the office for further details.

If the product is customised, the code is altered.

LATEST BLOG POSTS


The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026

All blog posts

Our lights are used by

I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporation
a project that was well planned and promptly accomplished
E. McHugh, Loganair
Where others let us down, Kellwood did not
W. Coley, Barking Abbey School
...my client is over the moon with the end results
A. Fraser, MacLean Electrical
I'd certainly recommend them
V. Richardson, Stolle Europe
I'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste