FR
FROSTED DIFFUSER
Asymmetric
Frosted
Measured, VAN-25B2-840-FR (taken as VAN-25B2-840-FR-D1-SM-WH, to confirm)
Industrial
Custodial Light
Order code VAN-25B2-840-FR-D1-SM-WH
No lumen is published for that combination.
25W nominal. 628 × 160 × 78 mm, 3.93 kg (excludes bracketry). Driver Boke. CE, RoHS.
The Vanguard Series Custodial Light is designed to provide safe, bright, uniform light for secure facilities. Its robust IK10++, fully welded anti-ligature housing includes anti-tamper features and an optional anti-shock device.
The recessed rear cable entry provides secure and inaccessible wiring connections that ensure the fitting remains flush with surfaces, mitigating vandalism.
Its water-resistant IP65 housing makes it suitable for both general-circulation spaces, and secure wash room facilities.
Additionally, its versatile housing profiles allow for both corner and ceiling mounting, offering flexibility in installation to suit various space configurations.
| Series code | VAN |
|---|---|
| Power | 10W to 44W, four settings per size |
| Efficacy | 130lm/W @ CRI>80, 5000K |
| Lumen output | 1,300lm to 5,720lm @ CRI>80, 5000K |
| Protection | IP65, IK10; steel body, 5mm polycarbonate lens |
| Lumen maintenance | L80B10 ≥100,000 hours (TM21 calculated) |
| Warranty | 5 Years |
Sheet lumen at CRI>80, 5000K, with no modification: 10 1,300 lm, 13 1,690 lm, 15 1,950 lm, 16 2,080 lm, 18 2,340 lm, 21 2,730 lm, 22 2,860 lm, 25 3,250 lm, 30 3,900 lm, 31 4,030 lm, 36 4,680 lm, 37 4,810 lm, 44 5,720 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 2 measured files give 134.5 to 141 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
FROSTED DIFFUSER
Asymmetric
Frosted
Measured, VAN-25B2-840-FR (taken as VAN-25B2-840-FR-D1-SM-WH, to confirm)
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
Anti-ligature housings: the triangular and low-profile rectangular (78mm deep) housings provide anti-ligature protection, and are suitable for corner, ceiling, and wall-mount applications. (Optional) Anti-Shock Device: in the unlikely event of unauthorised access, an (optional) internal anti-shock device can be included to protect residents and staff. IK10++ (150J) Shock Resistant Housing: the thick, 5mm polycarbonate diffuser and steel housing (with fully-welded seams) mitigates damage from vandalism. Anti-Tamper Security Screws: the diffuser is secured by anti-tamper security screws, lessening risk of unauthorised access to the internal components and main mounting points. Secure Mounting Points: internal mounting points are suitable for heavy-duty expansion bolt fixings, minimising the chance that the fitting can be dislodged from the wall or ceiling with force. A Range of Lumen and CCT Outputs, and Fitting Sizes: 2ft, 4ft, and 5ft housings, and 3000K and 4000K outputs up to 5,700 lumens, ensure that a solution can be optimised to safely light a cell, circulation area, or wash room, with appropriate illuminance and excellent uniformity. Recessed Rear Cable Entry: ensures the fitting remains flush with the ceiling or walls, mitigating gaps, that can lead to to vandalism. Water-Resistant White Finish: suitable for general purpose, and wet areas. Emergency: integrated 3hr emergency versions provide safe lighting in the event of power supply failure.


Inspection pit lighting design must consider illumination of the underside of the vehicle as well as the ground, ease of maintenance and impact resistance.

We provide lights for multi storey car parks, with lighting designs to meet CIBSE standards. Smart controls can also be used to help reduce running costs.
Showing 1-4 of 4
| Chip Brand, Model, & Size | Jufei 2835 |
|---|---|
| Light Emission | Direct |
| CCT | 5000K, (3000K, 4000K, 6500K optional) |
| CRI | ≥80Ra |
| SDCM | <3 |
| Diffusers | Frosted |
| Symmetric Light Distribution | 105° |
| Driver Brand | Boke |
|---|---|
| Input Voltage | 220-240VAC |
| Input Frequency | 50-60Hz |
| Qty of Drivers per Light | 1 |
| Power Factor | >0.9 |
| THD | <20% (220-240VAC) |
| Insulation Class | Class I |
| IP Rating | IP65 |
|---|---|
| IK Rating | IK10 |
| Ambient Usage Tolerance | -20°C to 40°C |
| Product Dimensions: LxWxH (mm) | A1 328 x 120 x 120; B1 628 x 120 x 120; B2 628 x 160 x 78; C1 1195 x 120 x 120; C2 1195 x 160 x 78; D1 1439 x 120 x 120; D2 1439 x 160 x 78 (1 corner, 2 rectangular) |
|---|---|
| Electrical Connection | Terminal Block |
| Fixture Weight (excludes bracketry) | A1 2.04kg; B1 3.25kg; B2 3.93kg; C1 6.56kg; C2 7.25kg; D1 7.75kg; D2 8.10kg |
| Fixture Primary Material(s) | Steel |
| Lens(es) Materials | UV Stabilised Polycarbonate (5mm) |
| Dimming Options | 1-10V, DALI |
|---|---|
| Compatible intelligent lighting systems | Wireless Controls and Monitoring |
| Mounting Styles | Surface Mounting |
|---|---|
| Available Product Colours | White, Black |
| A 1 10 | 10W nominal. 328 × 120 × 120 mm, 2.04 kg (excludes bracketry). Driver Boke. CE, RoHS. |
|---|---|
| A 1 13 | 13W nominal. 328 × 120 × 120 mm, 2.04 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| A 1 16 | 16W nominal. 328 × 120 × 120 mm, 2.04 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| A 1 18 | 18W nominal. 328 × 120 × 120 mm, 2.04 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 1 15 | 15W nominal. 628 × 120 × 120 mm, 3.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 1 18 | 18W nominal. 628 × 120 × 120 mm, 3.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 1 22 | 22W nominal. 628 × 120 × 120 mm, 3.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 1 25 | 25W nominal. 628 × 120 × 120 mm, 3.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 2 15 | 15W nominal. 628 × 160 × 78 mm, 3.93 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 2 18 | 18W nominal. 628 × 160 × 78 mm, 3.93 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 2 22 | 22W nominal. 628 × 160 × 78 mm, 3.93 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| B 2 25 | 25W nominal. 628 × 160 × 78 mm, 3.93 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 1 21 | 21W nominal. 1195 × 120 × 120 mm, 6.56 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 1 25 | 25W nominal. 1195 × 120 × 120 mm, 6.56 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 1 30 | 30W nominal. 1195 × 120 × 120 mm, 6.56 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 1 36 | 36W nominal. 1195 × 120 × 120 mm, 6.56 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 2 21 | 21W nominal. 1195 × 160 × 78 mm, 7.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 2 25 | 25W nominal. 1195 × 160 × 78 mm, 7.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 2 30 | 30W nominal. 1195 × 160 × 78 mm, 7.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| C 2 36 | 36W nominal. 1195 × 160 × 78 mm, 7.25 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 1 25 | 25W nominal. 1439 × 120 × 120 mm, 7.75 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 1 31 | 31W nominal. 1439 × 120 × 120 mm, 7.75 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 1 37 | 37W nominal. 1439 × 120 × 120 mm, 7.75 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 1 44 | 44W nominal. 1439 × 120 × 120 mm, 7.75 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 2 25 | 25W nominal. 1439 × 160 × 78 mm, 8.10 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 2 31 | 31W nominal. 1439 × 160 × 78 mm, 8.10 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 2 37 | 37W nominal. 1439 × 160 × 78 mm, 8.10 kg (excludes bracketry). Driver Boke. CE, RoHS. |
| D 2 44 | 44W nominal. 1439 × 160 × 78 mm, 8.10 kg (excludes bracketry). Driver Boke. CE, RoHS. |
The code starts with the wattage, then the size letter and the enclosure number: VAN-25B2 is 25W, 628mm, rectangular.
One data sheet covers every Vanguard application (custodial, inspection pit, spray booth, subway).
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste