60PC
60° circular
Symmetric
Clear
Drawn from the beam setting, not measured
Hazardous Area · Zone 1 and Zone 21
Explosion Proof Grain Store Lighting
Order code STA-120-757-120PC-V4-UB-GR-I1
No lumen is published for that combination.
120W nominal. 330 × 197 mm, 11.0 kg. CE, RoHS, ATEX, IECEx.
Kellwood's Stanford Series Grain Store variant is a purpose-built lighting solution for Zone 1 and Zone 2 hazardous areas, ideal for grain stores, food production, and other dust-prone environments where glass-free, explosion-proof lighting is essential.
With its robust polycarbonate diffuser and aluminium enclosure, the grain store variant removes the risk of glass contamination while delivering reliable performance in demanding conditions. Available in Standard and 3hr Maintained Emergency versions, it supports safety during both routine operations and unexpected power loss.
Offering a range of lumen outputs, optics, and mounting options, the Stanford Grain Store variant adapts easily to both targeted tasks and wide-area lighting. Wire-in-wire-out configurations and integrated emergency gear ensure a flexible, cost-effective solution for hazardous sites requiring dependable, compliant illumination.
| Series code | STA |
|---|---|
| Nominal power | 30W to 300W |
| Efficacy | 118lm/W to 127lm/W @ CRI>70 |
| Lumen output | 3,600lm to 33,000lm |
| Lumen maintenance | L70B50 ≥50,000 hours |
| Certification | CE, RoHS, ATEX, IECEx |
| Warranty | 5 Years, 3 Years (Emergency) |
No lumen row is entered yet. The order code still prints; the lumen stays blank.
Questions for Adam list what the sheet and the measured files do not settle yet.
60° circular
Symmetric
Clear
Drawn from the beam setting, not measured
80° circular
Symmetric
Clear
Drawn from the beam setting, not measured
120° circular
Symmetric
Clear
Drawn from the beam setting, not measured
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
The Stanford Series Grain Store variant has a selection of features that are of particular benefit for grain store, flour mills, and general food production applications: Glass-Free Construction: Built without glass components, reducing the risk of shattering and contamination in food-sensitive environments like grain storage areas. Ingress Protection (IP) Rating: Its high, IP66 rating, ensures dust-tight performance, essential in grain storage areas and mills. Corrosion-Resistant Housing: Constructed from robust, corrosion-resistant materials such as stainless steel or coated aluminium. ATEX/IECEx Certified: Certified for use in hazardous areas (Zone 2/22), making it compliant with safety regulations for explosive dust atmospheres typically present in grain handling facilities. Impact-Resistant Diffuser: Utilises polycarbonate, shatter-resistant materials for the diffuser, ensuring durability and safety during operation or maintenance. Optimised Light Distribution: Designed to provide wide and even light coverage, reducing shadows and improving visibility across large open areas like grain bins or silos. Integrated Emergency: Optional Remote-test 3hr emergency provides back-up illumination in the event of a power failure, allowing operatives to safely exit the area.


For farms and the agricultural sector, Kellwood Lighting offers a vast range of efficient LED Lighting options that will create significant energy savings

Lighting for Distilleries must find a balance between style and function; lights must offer optimum performance in vapour-filled environments.

Lighting for grain processing and storage rooms must work in the presence of flammable dust, meeting regulations for hazardous areas and food production.

For industrial food preparation areas and in commercial kitchens and catering production, we offer a choice of energy efficient LED lighting solutions.
Showing 1-4 of 5
| Chip Brand, Model, & Size | Lumiled Luxeon 5050 |
|---|---|
| Light Emission | Direct |
| CCT | 5700K, (3000K, 4000K, 5000K optional) |
| CRI | ≥70, (≥80 optional) |
| Diffusers | Clear |
| Symmetric Light Distribution | 60°, 80°, 120° |
| System Operating Power | STA-30: 30W; STA-45: 45W; STA-60: 60W; STA-80: 80W; STA-100: 100W; STA-120: 120W; STA-150: 150W; STA-200: 200W; STA-240: 240W; STA-300: 300W |
|---|---|
| System Power Factor | >0.9 |
| Input Voltage | 100-277VAC, 220-240VAC (Emergency) |
| Input Frequency | 50-60Hz |
| Power Factor | >0.98 |
| THD | <10% |
| Insulation Class | I |
| Surge Protection/Fusing | 5kV |
| IP Rating | IP66 |
|---|---|
| IK Rating | IK08 (IK10 front face with the wire guard) |
| Ambient Usage Tolerance | -40°C to 55°C, -20°C to 55°C (Emergency) |
| Ambient Storage Tolerance | -20°C to 55°C |
| Ambient Humidity Tolerance | 0% to 90% RH |
| Product Dimensions: ø x H (mm) | STA-30 to STA-80: 275 x 195; STA-100 to STA-150: 330 x 197; STA-200 to STA-300: 415 x 197 |
|---|---|
| Wire-In-Only Electrical Connection | Recommended 1mm² to 4mm² |
| Wire-In-Wire-Out Electrical Connection | Recommended 1mm² to 4mm² |
| Wire-In-Wire-Out Installation | Yes (up to 4 separate cable gland entries for 30W-240W) |
| Inlet Thread | M20 (M20x1.5), M25 (M25x1.5), NPT3/4” |
| Gland Type | Brass with Nickel Plated Non-Armoured (Armoured optional) |
| Suitable Cable Size (ø) | M20 = 6.1-13.2mm, M25 = 9.5-15.9mm, NPT3/4” = 12.5-20.5mm |
| Fixture Weight | STA-30 to STA-80: 8.5kg; STA-100 to STA-150: 11.0kg; STA-200 to STA-300: 14.0kg (excludes bracketry) |
| Fixture Primary Material(s) | ADC12 Aluminium Alloy (1.5-3.5% Copper) and 316 Stainless Steel Fixings |
| Fixture Finish | Epoxy Powder Coated |
| Lens(es) Materials | UV Stabilised Polycarbonate |
| Mounting Styles | Universal Bracket, Slip Fit, In-Line Pipe Connector, Eye Bolt |
|---|---|
| Miscellaneous Accessories | Wire Guard, Integrated Emergency (Remote Test) |
| Available Product Colours | Grey (RAL7040) |
| Emergency Variant Code | E3R1 |
|---|---|
| Test Method | Remote-Test |
| Style | Integrated |
| Output Power in Emergency Mode | 10W |
| Emergency Lumen Output @ 6000K CCT | 1,150 to 1,250lm |
| Emergency Correction Factor | STA-30: 0.333; STA-45: 0.222; STA-60: 0.166; STA-80: 0.125; STA-100: 0.100; STA-120: 0.083; STA-150: 0.066; STA-200: 0.050; STA-240: 0.041; STA-300: N/A |
| Battery Brand | Dison |
| Battery Model | HRH26/51(C) D-MH-20047 |
| Battery Chemical Composition | Ni-MH |
| Battery Capacity | 4000mAh |
| Output Power Duration | 3 hours |
| Time to Charge | 24 hours |
| 30 | 30W nominal. 275 × 195 mm, 8.5 kg. CE, RoHS, ATEX, IECEx. |
|---|---|
| 45 | 45W nominal. 275 × 195 mm, 8.5 kg. CE, RoHS, ATEX, IECEx. |
| 60 | 60W nominal. 275 × 195 mm, 8.5 kg. CE, RoHS, ATEX, IECEx. |
| 80 | 80W nominal. 275 × 195 mm, 8.5 kg. CE, RoHS, ATEX, IECEx. |
| 100 | 100W nominal. 330 × 197 mm, 11.0 kg. CE, RoHS, ATEX, IECEx. |
| 120 | 120W nominal. 330 × 197 mm, 11.0 kg. CE, RoHS, ATEX, IECEx. |
| 150 | 150W nominal. 330 × 197 mm, 11.0 kg. CE, RoHS, ATEX, IECEx. |
| 200 | 200W nominal. 415 × 197 mm, 14.0 kg. CE, RoHS, ATEX, IECEx. |
| 240 | 240W nominal. 415 × 197 mm, 14.0 kg. CE, RoHS, ATEX, IECEx. |
| 300 | 300W nominal. 415 × 197 mm, 14.0 kg. CE, RoHS, ATEX, IECEx. |
Footnote 1: emergency is only available with the 120° optic.
Footnote 2: the emergency version E3R1 is only available with 220-240 VAC (V11) input and for 30W to 240W.
Details are for the standard non-dimming driver. Fixture weights exclude bracketry.
IK rating format is housing / front face; IK10 when fitted with the wire guard.
Wire-in-wire-out products are supplied with one non-armoured ATEX certified gland and one ATEX certified blanking plug. Armoured cable glands are an option; contact Kellwood.
The stated cable size applies to the standard gland; armoured cable may vary.
Hazardous area certified product modifications are typically limited to bracketry, to keep certification. Products are supplied with OEM nameplates, codes and documentation corresponding to the certification.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
Modifications which affect light output have separate photometric files identified with +(modification).
Alternative drivers may be available. Contact the office for further details.
If the product is customised, the code is altered.
Contact the office for further information on driver parameters.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste