FR
120° frosted
Symmetric
Frosted
Measured, CAM2-20B-840-FR
Industrial · Linear
Legacy: the Cameron 2 clean-area linear, from its own data sheet. For new projects see the Crawford Series.
Order code CAM2-20B-850-FR-D1-TM-PC
No lumen is published for that combination.
20W nominal. 600 × 70 mm (L × Ø), 1.0 kg (excludes bracketry). Driver Lifud LF-GMD023YA. CE, RoHS.
Originally developed for spray-down use in caustic chemical rooms and clean-areas, the Cameron Series is corrosion-proof and durable, thus is effective in a far wider range of applications, including schools and sports complexes. Built to last, the technical standards and available modifications the Cameron family offers make for very impressive reading.
| Series code | CAM2 |
|---|---|
| Nominal power | 20W to 48W |
| Efficacy | 139 to 144lm/W @ CRI>80, 4000K |
| Lumen output | 2,531lm to 6,672lm @ CRI>80, 4000K |
| Protection | IP69K; IK10 (PC), IK08 (PMMA), IK06 (glass) |
| Lumen maintenance | L80B10 ≥55,000 hours reported; L70B50 ≥86,000 hours calculated |
| Warranty | 5 Years |
Sheet lumen at CRI>80, 4000K, with no modification: 20B 2,531 lm, 36D 5,184 lm, 48A 6,672 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 3 measured files give 137.9 to 144 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
120° frosted
Symmetric
Frosted
Measured, CAM2-20B-840-FR
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
Impact Protection: Stainless steel fixtures and polycarbonate diffuser provides an impact protection score of IK10 proving it to be a durable product. Cable Wiring: Cable entry uses a quick connector system using stainless steel gland with 3m cable. Parallel and series installation (daisy-chain max load 1200W) is possible with the Cameron Series. Ingress Rating: IP69K corrosion resistant provides a product capable of performing in various corrosive environments. Lumens: Across all three fitting lengths the Cameron Series has lumen output of 139lm/W to 144lm/W. When using the polycarbonate diffuser has a V0 fire rating and up to 90% light transmittance.

Showing 1-4 of 4
| Chip | Jufei San'an 2835 |
|---|---|
| CCT | 5000K (3000K, 4000K optional) |
| CRI | ≥80 (≥90 optional; >95 on request) |
| SDCM | <6 (<3 optional) |
| Diffuser | Frosted polycarbonate, PMMA or tempered glass |
| Distribution | 120° |
| Typical UGR | 20W <24; 36W <22; 48W <21 |
| Driver | Lifud LF-GMD023YA (20W), LF-GMD040YA (36W), LF-GMD063YA (48W) |
|---|---|
| Input Voltage | 220-240VAC, 50-60Hz |
| Inrush current | <60A / 350μs @ 230VAC |
| Max wired in series | 20W 35; 36W 19; 48W 14 (daisy chain max 1200W) |
| Power Factor | >0.9 |
| THD | <20% |
| Insulation Class | Class I |
| Dimming | 1-10V, DALI |
| IP Rating | IP69K |
|---|---|
| IK Rating | IK10 (PC) / IK08 (PMMA) / IK06 (TG) |
| Ambient Usage Tolerance | -20°C to 40°C |
| Ambient Storage Tolerance | -40°C to 85°C |
| Humidity | 10% to 80% RH |
| Dimensions (L x Ø) | 600 x 70; 1200 x 70; 1500 x 70mm |
|---|---|
| Electrical connection | 1000mm 3-core cable |
| Housing | Polycarbonate or PMMA with aluminium internal structure; 316 stainless steel fixings and end caps |
| Fire rating | V0 (polycarbonate housing) |
| 20B | 20W nominal. 600 × 70 mm (L × Ø), 1.0 kg (excludes bracketry). Driver Lifud LF-GMD023YA. CE, RoHS. |
|---|---|
| 36D | 36W nominal. 1200 × 70 mm (L × Ø), 1.7 kg (excludes bracketry). Driver Lifud LF-GMD040YA. CE, RoHS. |
| 48A | 48W nominal. 1500 × 70 mm (L × Ø), 2.0 kg (excludes bracketry). Driver Lifud LF-GMD063YA. CE, RoHS. |
Seamless cylindrical design resists dirt and dust build-up; suitable for food-grade areas.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste