25
25° circular
Symmetric
Clear
Drawn from the beam setting, not measured
Industrial · Floodlight
Modular general-purpose floodlights and high bays, 75W to 450W, with flood and racking optics.
Order code FOR2B-100-750-110-D1-UB-GR
15,400 lm
CRI>70, 5000K. 110° circular optic. GR grey (RAL 7045).
No lumen is published for that combination.
100W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
The Forsyth Series are a range of modular LED floodlights designed to provide a flexible lighting solution, where simple general asymmetric flood optics are required for general area lighting. Applications include yard or compound lighting.
Progressive 75W modules, ingress and impact resistance (IP66, IK10) and stainless steel fixings make it a multi-purpose industrial fitting for workshops, warehouses, sheds and factories, with optional photocell, PIR and microwave sensors.
Environmental upgrades include an enhanced corrosion resistant finish.
| Series code | FOR2B |
|---|---|
| Nominal power | 75W to 450W |
| Efficacy | 137 to 154 lm/W at CRI>70, 4000K/5000K |
| Lumen output | 10,275 to 63,000 lm |
| Lumen maintenance | L70B50 ≥100,000 hours @ 25°C ambient (TM21 calculated) |
| Certification | CE, RoHS, ETL |
| Warranty | 5 Years |
Sheet lumen at CRI>70, 4000K or CRI>70, 5000K, with no modification: 75 10,275 lm, 75 10,275 lm, 100 15,400 lm, 100 15,400 lm, 150 21,000 lm, 150 21,000 lm, 200 29,000 lm, 200 29,000 lm, 240 32,880 lm, 240 32,880 lm, 300 42,000 lm, 300 42,000 lm, 450 63,000 lm, 450 63,000 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 84 measured files give 119.9 to 141.8 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
25° circular
Symmetric
Clear
Drawn from the beam setting, not measured
30° circular
Symmetric
Clear
Measured, FOR2-100-750-30 (taken as FOR2B-100-750-30, to confirm)
60° circular
Symmetric
Clear
Drawn from the beam setting, not measured
90° circular
Symmetric
Clear
Measured, FOR2-100-750-90 (taken as FOR2B-100-750-90, to confirm)
110° circular
Symmetric
Clear
Measured, FOR2-100-750-110 (taken as FOR2B-100-750-110, to confirm)
140° circular
Symmetric
Clear
Drawn from the beam setting, not measured
30 × 100° rectangular
Asymmetric
Clear
Measured, FOR2-100-850-A1 (taken as FOR2B-100-850-A1, to confirm)
60 × 100° rectangular
Asymmetric
Clear
Measured, FOR2-100-750-A2 (taken as FOR2B-100-750-A2, to confirm)
IESNA Type II Short (70° × 130°)
Asymmetric
Clear
Measured, FOR2-100-750-2S (taken as FOR2B-100-750-2S, to confirm)
IESNA Type II Medium (80° × 150°)
Asymmetric
Clear
Measured, FOR2-100-750-2M (taken as FOR2B-100-750-2M, to confirm)
IESNA Type III Short (80° × 145°)
Asymmetric
Clear
Drawn from the beam setting, not measured
IESNA Type III Medium (80° × 150°)
Asymmetric
Clear
Measured, FOR2-100-750-3M (taken as FOR2B-100-750-3M, to confirm)
IESNA Type IV Short (85° × 125°)
Asymmetric
Clear
Measured, FOR2-100-750-4S (taken as FOR2B-100-750-4S, to confirm)
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
With an efficacy of ≥140lm/W, the Performance 2 Series has multiple optional light distribution patterns and intelligent lighting controls offering maximum flexibility and capability for any lighting requirements. Optics: Forsyth Series has a flexible range of optics to provide lighting for a wide range of applications: 90°, 110°, 150°, A1 (30X100° Rectangular), A2 (60X100° Rectangular), 1S (IESNA Type I Short), 2S (IESNA Type II Short), 4S (IESNA Type IV Short), 2M (IESNA Type II Medium). Lumen Maintenance: Through design to lower thermal temperatures with modular light engine, chassis design and premium components contributes to having a long product usage lifetime. Lumen Maintenance is L70B50 >82,000 hours. Intelligent Lighting Controls: Optional intelligent light controls available are: photocell, microwave sensor (remote control), PIR sensor. Mounting: To provide lighting to a wide range of applications it requires several mounting options: universal bracket (180° rotation optional), slip fit, twin surface mount brackets, eye bolt, twin eye bolts, wall mount.


High quality Badminton court lighting solutions designed to meet any specifications. Kellwood Lighting aims to provide the best solution for all budgets.

When considering security lights, we offer a vast range of robust, efficient, high quality security LED lighting systems, from bulkheads to floodlights.

Kellwood's expert workshop lighting solutions meet CIBSE and HSE guidance. Our systems enhance safety, accuracy and efficiency in all types of workshops.

Vast range of LED warehouse high bay lights, low bay lights and other warehouse lighting fixtures, including lights suitable for commercial storage spaces.

Designed to meet CIBSE and HSE standards, our lighting systems improve safety, visibility and compliance across manufacturing and industrial environments.

We offer specialist railway yard lighting design, providing high mast and LED floodlight solutions for National Rail and third-party operators.

Custom lighting solutions to accommodate the diverse range of activities held within a public or private sports hall.
Showing 1-4 of 8
| Chip | Philips Lumileds |
|---|---|
| Chip efficacy | 169 lm/W @ 122mA, 25°C, CRI>70, 5000K |
| Distribution | Direct |
| CCT | 5000K (3000K, 4000K, 6000K) |
| CRI | ≥70Ra (≥80Ra optional) |
| SDCM | ≤5 |
| Diffuser | Clear |
| Symmetric | 25°, 30°, 60°, 90°, 110° (standard), 140° |
| Asymmetric | A1 (30°×100°), A2 (60°×100°), 2S, 2M, 3S, 3M, 4S |
| Driver | Mean Well (Inventronics DALI-dimming optional) |
|---|---|
| Driver lifetime | 100,000 hours @ Ta 25°C |
| Supply | 220-240VAC |
| Frequency | 50-60Hz |
| Power factor | >0.95 |
| THD | <15% (220-240VAC) |
| Insulation | Class I |
| Surge | 4kV L-L, 6kV L-E / 2kV line-line, 4kV line-earth (both printed) |
| Electrical note | These electrical figures are for D1 drivers, unless the sheet says otherwise. |
| IP | IP66 |
|---|---|
| IK | IK10 |
| Ambient | −30 to 45°C |
| Storage | −40 to 80°C |
| Driver turn-off | 90°C Tc: the driver powers off to protect the LED load |
| Humidity | 15 to 95% RH |
| Connection | 1000mm 3-core cable |
|---|---|
| Body | Aluminium alloy and stainless steel fixings |
| Finish | Painted |
| Lens | UV stabilised polycarbonate |
| Dimming | 1-10V, DALI |
|---|---|
| Built-in | Photocell, PIR sensor |
| Mounting | Universal bracket (optional 180° rotation), slip fit, twin surface mount brackets, eye bolt, twin eye bolts |
| Accessories | Wire grill, corrosion resistant finish, IP68 13A in-line connector (JB1), photocell, PIR sensor, microwave sensor |
| Colours | Black (RAL 9017), Grey (RAL 7045) |
| Systems | Wireless controls and monitoring, photocell |
| 75 | 75W nominal. 214 × 365 × 224 mm, 1 module, 5.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
|---|---|
| 100 | 100W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
| 150 | 150W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
| 200 | 200W nominal. 435 × 365 × 224 mm, 3 modules, 7.7 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
| 240 | 240W nominal. 435 × 365 × 224 mm, 3 modules, 7.7 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
| 300 | 300W nominal. 540 × 365 × 224 mm, 4 modules, 9.1 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
| 450 | 450W nominal. 750 × 365 × 224 mm, 6 modules, 14.9 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL. |
Universal bracket (UB) rotation on a solid surface is restricted: 100W ±60°, 150W ±45°, 200W ±20°. 300W and 450W are not available with UB; specify UE.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste