KKELLWOODLIGHTING Tel 01387 255 816Edit seriesOffice

Industrial · Floodlight

Forsyth Series - Multi-Functional Floodlights

Modular general-purpose floodlights and high bays, 75W to 450W, with flood and racking optics.

  • 75W to 450W
  • 10,275 to 63,000 lm
  • 137 to 154 lm/W
  • IP66
  • 5 Years warranty

Order code FOR2B-100-750-110-D1-UB-GR

15,400 lm

CRI>70, 5000K. 110° circular optic. GR grey (RAL 7045).

Measured file FOR2-100-750-110 (taken as FOR2B-100-750-110, to confirm): 14,072 lm at 100 W (140.7 lm/W).

100W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.

Request a quote

Forsyth 2B series floodlight

BUILD THIS FITTING

Order code FOR2B-100-750-110-D1-UB-GR

15,400 lm

CRI>70, 5000K. 110° circular optic. GR grey (RAL 7045).

Measured file FOR2-100-750-110 (taken as FOR2B-100-750-110, to confirm): 14,072 lm at 100 W (140.7 lm/W).

100W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.

CIBSE target · 200 lx

Lux does not change the order code.

My schedule

Request a lighting design

Modification

  • CE
  • 140 lm/W
  • 5 years
  • IK10
  • IP66
  • 45°C
  • Dimmable

The Forsyth Series are a range of modular LED floodlights designed to provide a flexible lighting solution, where simple general asymmetric flood optics are required for general area lighting. Applications include yard or compound lighting.

Progressive 75W modules, ingress and impact resistance (IP66, IK10) and stainless steel fixings make it a multi-purpose industrial fitting for workshops, warehouses, sheds and factories, with optional photocell, PIR and microwave sensors.

Environmental upgrades include an enhanced corrosion resistant finish.

Request a quote or a lighting design. Kellwood prices the fitting. The order code goes with the request.

Order code FOR2B-100-750-110-D1-UB-GR

Performance summary
Series codeFOR2B
Nominal power75W to 450W
Efficacy137 to 154 lm/W at CRI>70, 4000K/5000K
Lumen output10,275 to 63,000 lm
Lumen maintenanceL70B50 ≥100,000 hours @ 25°C ambient (TM21 calculated)
CertificationCE, RoHS, ETL
Warranty5 Years

Sheet lumen at CRI>70, 4000K or CRI>70, 5000K, with no modification: 75 10,275 lm, 75 10,275 lm, 100 15,400 lm, 100 15,400 lm, 150 21,000 lm, 150 21,000 lm, 200 29,000 lm, 200 29,000 lm, 240 32,880 lm, 240 32,880 lm, 300 42,000 lm, 300 42,000 lm, 450 63,000 lm, 450 63,000 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 84 measured files give 119.9 to 141.8 lm/W; the measured figure for the chosen optic shows under the code.

DOWNLOADS

Questions for Adam list what the sheet and the measured files do not settle yet.

LIGHT DISTRIBUTION OPTIONS


25

90°60°30°0°30°60°90°
Polar

25° circular

Symmetric

Clear

Drawn from the beam setting, not measured

30

90°60°30°0°30°60°90°
Polar
±0.5 H
Isolux

30° circular

Symmetric

Clear

Measured, FOR2-100-750-30 (taken as FOR2B-100-750-30, to confirm)

60

90°60°30°0°30°60°90°
Polar

60° circular

Symmetric

Clear

Drawn from the beam setting, not measured

90

90°60°30°0°30°60°90°
Polar
±1.5 H
Isolux

90° circular

Symmetric

Clear

Measured, FOR2-100-750-90 (taken as FOR2B-100-750-90, to confirm)

110

90°60°30°0°30°60°90°
Polar
±1.75 H
Isolux

110° circular

Symmetric

Clear

Measured, FOR2-100-750-110 (taken as FOR2B-100-750-110, to confirm)

140

90°60°30°0°30°60°90°
Polar

140° circular

Symmetric

Clear

Drawn from the beam setting, not measured

A1

90°60°30°0°30°60°90°
Polar
±1.5 H
Isolux

30 × 100° rectangular

Asymmetric

Clear

Measured, FOR2-100-850-A1 (taken as FOR2B-100-850-A1, to confirm)

A2

90°60°30°0°30°60°90°
Polar
±1.5 H
Isolux

60 × 100° rectangular

Asymmetric

Clear

Measured, FOR2-100-750-A2 (taken as FOR2B-100-750-A2, to confirm)

2S

90°60°30°0°30°60°90°
Polar
±2.5 H
Isolux

IESNA Type II Short (70° × 130°)

Asymmetric

Clear

Measured, FOR2-100-750-2S (taken as FOR2B-100-750-2S, to confirm)

2M

90°60°30°0°30°60°90°
Polar
±3 H
Isolux

IESNA Type II Medium (80° × 150°)

Asymmetric

Clear

Measured, FOR2-100-750-2M (taken as FOR2B-100-750-2M, to confirm)

3S

90°60°30°0°30°60°90°
Polar

IESNA Type III Short (80° × 145°)

Asymmetric

Clear

Drawn from the beam setting, not measured

3M

90°60°30°0°30°60°90°
Polar
±3 H
Isolux

IESNA Type III Medium (80° × 150°)

Asymmetric

Clear

Measured, FOR2-100-750-3M (taken as FOR2B-100-750-3M, to confirm)

4S

90°60°30°0°30°60°90°
Polar
±2.75 H
Isolux

IESNA Type IV Short (85° × 125°)

Asymmetric

Clear

Measured, FOR2-100-750-4S (taken as FOR2B-100-750-4S, to confirm)

Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.

DESIGN FEATURES


Floodlights designed for PURPOSE

With an efficacy of ≥140lm/W, the Performance 2 Series has multiple optional light distribution patterns and intelligent lighting controls offering maximum flexibility and capability for any lighting requirements. Optics: Forsyth Series has a flexible range of optics to provide lighting for a wide range of applications: 90°, 110°, 150°, A1 (30X100° Rectangular), A2 (60X100° Rectangular), 1S (IESNA Type I Short), 2S (IESNA Type II Short), 4S (IESNA Type IV Short), 2M (IESNA Type II Medium). Lumen Maintenance: Through design to lower thermal temperatures with modular light engine, chassis design and premium components contributes to having a long product usage lifetime. Lumen Maintenance is L70B50 >82,000 hours. Intelligent Lighting Controls: Optional intelligent light controls available are: photocell, microwave sensor (remote control), PIR sensor. Mounting: To provide lighting to a wide range of applications it requires several mounting options: universal bracket (180° rotation optional), slip fit, twin surface mount brackets, eye bolt, twin eye bolts, wall mount.

Floodlights designed for PURPOSE

TYPICAL APPLICATIONS


SPECIFICATIONS


Light source
ChipPhilips Lumileds
Chip efficacy169 lm/W @ 122mA, 25°C, CRI>70, 5000K
DistributionDirect
CCT5000K (3000K, 4000K, 6000K)
CRI≥70Ra (≥80Ra optional)
SDCM≤5
DiffuserClear
Symmetric25°, 30°, 60°, 90°, 110° (standard), 140°
AsymmetricA1 (30°×100°), A2 (60°×100°), 2S, 2M, 3S, 3M, 4S
Electrical
DriverMean Well (Inventronics DALI-dimming optional)
Driver lifetime100,000 hours @ Ta 25°C
Supply220-240VAC
Frequency50-60Hz
Power factor>0.95
THD<15% (220-240VAC)
InsulationClass I
Surge4kV L-L, 6kV L-E / 2kV line-line, 4kV line-earth (both printed)
Electrical noteThese electrical figures are for D1 drivers, unless the sheet says otherwise.
Environmental
IPIP66
IKIK10
Ambient−30 to 45°C
Storage−40 to 80°C
Driver turn-off90°C Tc: the driver powers off to protect the LED load
Humidity15 to 95% RH
Physical
Connection1000mm 3-core cable
BodyAluminium alloy and stainless steel fixings
FinishPainted
LensUV stabilised polycarbonate
Dimming and options
Dimming1-10V, DALI
Built-inPhotocell, PIR sensor
MountingUniversal bracket (optional 180° rotation), slip fit, twin surface mount brackets, eye bolt, twin eye bolts
AccessoriesWire grill, corrosion resistant finish, IP68 13A in-line connector (JB1), photocell, PIR sensor, microwave sensor
ColoursBlack (RAL 9017), Grey (RAL 7045)
SystemsWireless controls and monitoring, photocell
Each body (size and weight exclude bracketry)
7575W nominal. 214 × 365 × 224 mm, 1 module, 5.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
100100W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
150150W nominal. 330 × 365 × 224 mm, 2 modules, 6.4 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
200200W nominal. 435 × 365 × 224 mm, 3 modules, 7.7 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
240240W nominal. 435 × 365 × 224 mm, 3 modules, 7.7 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
300300W nominal. 540 × 365 × 224 mm, 4 modules, 9.1 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.
450450W nominal. 750 × 365 × 224 mm, 6 modules, 14.9 kg. Driver Mean Well (D1, D2), Inventronics (D3). CE, RoHS, ETL.

Universal bracket (UB) rotation on a solid surface is restricted: 100W ±60°, 150W ±45°, 200W ±20°. 300W and 450W are not available with UB; specify UE.

LATEST BLOG POSTS


The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026

All blog posts

Our lights are used by

I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporation
a project that was well planned and promptly accomplished
E. McHugh, Loganair
Where others let us down, Kellwood did not
W. Coley, Barking Abbey School
...my client is over the moon with the end results
A. Fraser, MacLean Electrical
I'd certainly recommend them
V. Richardson, Stolle Europe
I'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste