70
70° circular
Symmetric
Frosted
Drawn from the beam setting, not measured
Commercial · Linear
High-Ouput T8 LED Tubes
Order code HES-11A-850-120-D1-RT
No lumen is published for that combination.
11W nominal. 588 mm long × Ø26 mm, 0.155 kg. Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE.
Kellwood's Heston Series range LED T8 tubes were developed as a multi-purpose solution for existing fluorescent tube replacement. Ultra-high efficacy chips produce more light and less heat than competitor products allowing for lower running costs, brighter fixtures and longer lifetimes.
| Series code | HES |
|---|---|
| Nominal power | 11W to 30W |
| Efficacy | 140 to 152lm/W @ CRI>80, 4000K |
| Lumen output | 1,540lm to 4,470lm @ CRI>80, 4000K |
| Lumen maintenance | L70B50 ≥50,000 hours @ 25°C (TM21 reported) |
| Certification | CE, RoHS, TUV, SAA & VOE |
| Warranty | 5 Years |
Sheet lumen at CRI>80, 4000K, with no modification: 11A 1,540 lm, 15B 2,175 lm, 18C 2,736 lm, 23D 3,496 lm, 30D 4,470 lm, 30E 4,440 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 5 measured files give 140.4 to 152.6 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
70° circular
Symmetric
Frosted
Drawn from the beam setting, not measured
120° circular
Symmetric
Frosted
Measured, HES-10A-840-120-FR (taken as HES-11A-840-120, to confirm)
220° circular
Symmetric
Frosted
Drawn from the beam setting, not measured
DOUBLE 120° OPTIC
Asymmetric
Frosted
Drawn from the beam setting, not measured
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
A variety of lengths, wattages and beam angles make the Heston Series well suited for a wide range of retrofit applications whilst optional locking rotatable end caps simplify installation. A range of CCT and optional CRI 95 ensure the Heston series can be used in both industrial and commercial applications.


We offer a selection of office lighting, LED Office Lighting includes a choice of LED ceiling lights, ceiling panel lights, linear fittings and downlights.

Kellwood's expert workshop lighting solutions meet CIBSE and HSE guidance. Our systems enhance safety, accuracy and efficiency in all types of workshops.

Designed to meet CIBSE and HSE standards, our lighting systems improve safety, visibility and compliance across manufacturing and industrial environments.

Vast range of LED warehouse high bay lights, low bay lights and other warehouse lighting fixtures, including lights suitable for commercial storage spaces.
Showing 1-3 of 3
| Chip Brand, Model, & Size | Jufei San’an 2835 |
|---|---|
| Chip Efficacy @ CRI>80, 5000K CCT | 190lm/W @ 60mA, 25°C |
| Light Emission | Direct |
| CCT | 4000K, (3000K, 5000K, 6500K) |
| CRI | ≥80Ra, (≥90Ra optional) |
| SDCM | <5, (<3 optional) |
| Diffusers | Frosted, (Clear optional) |
| Symmetric Light Distribution | 70°, 120°, 220° circular |
| Double optic (D120) | 2 x 120° |
| Typical UGR | <24 |
| System Operating Power | 11W, 15W, 18W, 23W, 30W |
|---|---|
| Driver Brand | Letron internal non-dim (D1); external XY Power 1-10V (D2) or Inventronics DALI (D3) |
| Input Voltage | 220-240VAC |
| Input Frequency | 50-60Hz |
| Power Factor | >0.95 |
| THD | <10% (220-240VAC), <20% (100-277VAC) |
| Insulation Class | Class II |
| IP Rating | IP20 |
|---|---|
| IK Rating | IK06 |
| Ambient Usage Tolerance | -20°C to 40°C |
| Ambient Storage Tolerance | -40°C to 85°C |
| Ambient Humidity Tolerance | 10% to 85% RH |
| Length x diameter (mm) | 2ft 588 x 26; 3ft 894 x 26; 4ft 1196 x 26; 5ft 1498 x 26; 6ft 1763 x 26 |
|---|---|
| Fixture Weight | HES-11A: 0.155kg; HES-15B: 0.217kg; HES-18C: 0.271kg; HES-23D: 0.0342kg; HES-30D: 0.0342kg; HES-30E: 0.386kg |
| Fixture Primary Material(s) | Aluminium |
| Fixture Finish | Anodised |
| Lens(es) Materials | UV Stabilised Polycarbonate |
| Dimming Options | 1-10V, DALI |
|---|---|
| Compatible intelligent lighting systems | Wireless Controls and Monitoring |
| Mounting Styles | Fixed end caps (FI), rotatable locking end caps (RT) |
|---|
| 11A | 11W nominal. 588 mm long × Ø26 mm, 0.155 kg. Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
|---|---|
| 15B | 15W nominal. 894 mm long × Ø26 mm, 0.217 kg. Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
| 18C | 18W nominal. 1196 mm long × Ø26 mm, 0.271 kg. Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
| 23D | 23W nominal. 1498 mm long × Ø26 mm, 0.0342 kg (as printed). Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
| 30D | 30W nominal. 1498 mm long × Ø26 mm, 0.0342 kg (as printed). Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
| 30E | 30W nominal. 1763 mm long × Ø26 mm, 0.386 kg. Driver Letron internal (D1); XY Power external (D2); Inventronics external (D3). CE, RoHS, TUV, SAA & VOE. |
Fits standard T8 fittings. D1 has an isolated internal driver; dimming versions use external 1-10V or DALI drivers.
The tube is frosted as standard; CL fits a clear cover.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste