120
120° circular
Symmetric
Clear
Drawn from the beam setting, not measured
Hazardous Area · Floodlight
Battery Powered Work Lights
Order code SIN2-10-857-120-B1-FS-OR
1,260 lm
CRI>80, 5700K. 120° circular optic. OR Orange (RAL2011) - C5 rated.
No lumen is published for that combination.
10W nominal. 210 × 182 × 282 mm, 5.3 kg. CE, RoHS, ATEX.
A portable battery powered work light for use in explosive environments; the ideal companion for regular maintenance work in the, oil and gas, power-generation, and marine sectors. The Sinclair Series is powered through a rechargeable battery and can be mounted on an adjustable magnetic floor stand or surface mounted.
| Series code | SIN2 |
|---|---|
| Nominal power | 10W |
| Efficacy | 126lm/W @ CRI>80, 5700K CCT |
| Lumen output | 1,260lm |
| Lumen maintenance | L80B10 ≥50,000 hours @ 25°C ambient (TM21 reported), ≥76,685 hours (TM21 calculated) |
| Battery | 18VDC, 10 hours running from full charge, 7 hours to charge |
| Certification | CE, RoHS, ATEX |
| Warranty | 3 Years |
Sheet lumen at CRI>80, 5700K, with no modification: 10 1,260 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank.
Questions for Adam list what the sheet and the measured files do not settle yet.
120° circular
Symmetric
Clear
Drawn from the beam setting, not measured
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
The Sinclair Series has a 10W output and is supplied with 130lm/W high efficacy Seoul LED chips. This combination provides a portable lighting product with an 1300 lumen output. High ingress and impact protection (IK10 with the optional wire guard accessory) ensures product suitability across multiple work areas. Mounting: The Sinclair Series offers two mounting options; floor stand and magnetic stand (magnetic stand attaches securely to ferrous materials >3mm thick). Battery: The Lithium-Ion battery has a charging time of 7 hours, and provides a running time of 10 hours, allowing for daily use. Impact Resistance: Risk of early failure is significantly lowered through the use of a shock and vibration-resistant tempered glass lens and industrial aluminium alloy housing. Which can withstand up to 20J of force. Environmental Protection: It offers IP66 protection by using aluminium body that comes with corrosion resistant paint finish - Salt spray testing reports available. ATEX Rated - Zone 1 and Zone 2 suitable


These lights provide sufficient coverage for vehicle loading and unloading of Hazardous Substances while providing resistance against hazardous conditions.

Inspection pit lighting design must consider illumination of the underside of the vehicle as well as the ground, ease of maintenance and impact resistance.

Oil rig lights need to perform in harsh environments where safety is paramount. We offer a variety of LED ATEX explosion-proof lighting for oil rigs.

ATEX lights for paint shops and spray booths. Lux levels and specialist paint shop and spray booth lights for hazardous-area product finishing.

Lighting for Distilleries must find a balance between style and function; lights must offer optimum performance in vapour-filled environments.

Lighting for grain processing and storage rooms must work in the presence of flammable dust, meeting regulations for hazardous areas and food production.
Showing 1-3 of 3
| Chip Brand, Model, & Size | Osram Duris S5 |
|---|---|
| Chip Efficacy @ CRI>70, 5000K CCT | 151lm/W |
| Light Emission | Direct |
| CCT | 5700K, (3000K, 4000K, 5000K optional) |
| CRI | ≥80 |
| Diffusers | Clear |
| Symmetric Light Distribution | 120° |
| System Operating Power | 10W |
|---|---|
| Input Voltage (battery charger) | 100-277VAC |
| Input Frequency (battery charger) | 50-60Hz |
| Power Factor (battery charger) | >0.98 |
| THD (battery charger) | <10% (100VAC-277VAC) |
| Running Time (from full charge) | 10 hours |
| Charging Time (from full discharge) | 7 hours |
| Lifespan (charge cycles) | 500 |
| Insulation Class | III |
| IP Rating | IP66 |
|---|---|
| IK Rating | IK10 housing / IK08 front face, or IK10 / IK10 with the wire guard |
| Ambient Usage Tolerance | -20°C to 55°C |
| Marine Resistance Rating | C5 |
| Ambient Storage Tolerance | -20°C to 55°C |
| Ambient Humidity Tolerance | 0% to 90% RH |
| Product Dimensions: LxWxH (mm) | 210 x 182 x 282 |
|---|---|
| Qty of LED Chips | 39 |
| Electrical Connection | Battery charger supplied with UK 3-pin plug (Europlug, US plug optional) |
| Fixture Weight | 5.3kg (excludes bracketry) |
| Fixture Primary Material(s) | ADC12 Aluminium Alloy (1.5-3.5% Copper) and 316 Stainless Steel Fixings |
| Fixture Finish | Epoxy Powder Coated |
| Lens(es) Materials | Tempered Glass |
| Protection Method | Flame Proof |
| Mounting Styles | Floor Stand (304 stainless steel), Magnetic Stand |
|---|---|
| Miscellaneous Accessories | Wire Grill |
| Available Product Colours | Orange (RAL2011) |
| Division | ATEX Zone 1 & 21 and 2 & 22 |
|---|---|
| Product marking | II 2 G D, Ex db IIC T* Gb, Ex tb IIIC T* Db |
| Temperature class, -20°C to 55°C (Ta) | Gas T6, dust T80°C (10W) |
| Certificate numbers | ATEX: EPT 18 ATEX 2977 X issue 2; IECEx: IECEx CQM 15.0039X |
| 10 | 10W nominal. 210 × 182 × 282 mm, 5.3 kg. CE, RoHS, ATEX. |
|---|
IK rating format is housing / front face; IK10 front face when fitted with the wire guard. Fixture weight excludes bracketry.
Hazardous area certified product modifications are typically limited to bracketry, to keep certification. Products are supplied with OEM nameplates, codes and documentation corresponding to the certification.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
Modifications which affect light output have separate photometric files identified with +(modification).
Alternative drivers may be available. Contact the office for further details.
If the product is customised, the code is altered.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste