90
90° OPTIC
Symmetric
Clear
Measured, ARR-100-840-90
Sports · Floodlight
Linear Sports Luminaires
Order code ARR-100-840-90-D1-SM
12,900 lm
CRI>80, 4000K. 90° OPTIC optic.
No lumen is published for that combination.
Measured file ARR-100-840-90: 12,904 lm at 100.89 W (127.9 lm/W).
100W nominal. 1530 × 360 × 93 mm, 11.5 kg (excludes bracketry). CE, RoHS.
The Arran Series linear sports light is designed to provide a unique and flexible solution for sports hall applications.
As part of Kellwood Lighting's sports lighting product range, the Arran Series is DIN 18032-3 certified, and IK10 impact resistant to withstand ball-strikes.
Dimming options are available to satisfy multi-use facilities, e.g. those used for various sports requiring different lux levels, or for exams.
Tool-less removal of the front low-glare protective grill ensures the fitting is simple to install, and easily maintained.
| Series code | ARR |
|---|---|
| Nominal power | 100W to 200W |
| Efficacy | 121lm/W to 129lm/W @ CRI>80, 4000K CCT |
| Lumen output | 12,900lm to 24,200lm |
| Lumen maintenance | L80B10 ≥80,000 hours |
| Certification | CE, RoHS; ball impact resistance to DIN 18032-3 |
| Warranty | 5 Years |
Sheet lumen at CRI>80, 4000K, with no modification: 100 12,900 lm, 150 19,200 lm, 200 24,200 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 3 measured files give 121.8 to 128.7 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
90° OPTIC
Symmetric
Clear
Measured, ARR-100-840-90
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
Glare has been carefully managed by ensuring the LEDs are both diffused and recessed inside the fitting. This helps reduce direct line-of-sight of the light emitting surface, reduce glare and ensure compliance with the maximum UGR levels recommended by an individual sport's governing body. Incorporation of a robust frame and grill to mitigate against impact damage from indoor ball sports, including cricket, tennis, handball, squash, and football. The resulting luminaire is compliant with DIN 18032-3 for ball impact. CRI>80 4000K LED chips and DALI dimmable driver options allow for a multi-purpose use of illuminated space, including as an examination hall. Usability for new-builds and refurbishments is enhanced with surface and suspension mount options, as well as wire-in-wire-out installation and rear and end cable entrys. New Build & Retrofit: a suitable replacement for traditional linear fluorescent or low bay and high bay fittings, with simple installation requirements. Intelligent Controls: optional DALI functionality permits dimming through typical dimmer switches and also compatibility with Wireless Control Systems.


Custom lighting solutions to accommodate the diverse range of activities held within a public or private sports hall.

High quality Badminton court lighting solutions designed to meet any specifications. Kellwood Lighting aims to provide the best solution for all budgets.

Outdoor tennis court floodlights and low glare indoor tennis court lighting, with appropriate LUX levels for the environment, operated via smart controls.

Stadium, pitch and astro turf lighting solutions to ensure the highest quality of football.
Showing 1-4 of 4
| Light Emmission | Direct |
|---|---|
| CCT | 3000K, 4000K, 5000K, 6500K |
| CRI | ≥80 |
| SDCM | <5, (<3 optional ) |
| Diffusers | Clear |
| Symmetric Light Distribution | 90° |
| Typical UGR (varies with light distribution) | ARR-100: <19; ARR-150: <20; ARR-200: <22 |
| System Operating Power | ARR-100: 100W; ARR-150: 150W; ARR-200: 200W |
|---|---|
| System Power Factor | >0.93 |
| Input Voltage | 220-240VAC |
| Input Frequency | 50-60Hz |
| THD | <20% (220-240VAC) |
| IP Rating | IP40 |
|---|---|
| IK Rating | IK10 |
| Ball impact resistance | Certified to DIN 18032-3 |
| Ambient Usage Tolerance | -20°C to 40°C |
| Ambient Storage Tolerance | -40°C to 85°C |
| Ambient Humidity Tolerance | 15% to 90% RH |
| Product Dimensions: LxWxH (mm) | 1530 x 360 x 93 |
|---|---|
| Fixture Weight | 11.5kg (excludes bracketry) |
| Lens(es) Materials | UV Stabilised PMMA recessed behind protective grill |
| Dimming Options | DALI |
|---|---|
| Compatible intelligent lighting systems | Wireless Controls and Monitoring |
| Mounting Styles | Surface mounted, cable suspended |
|---|---|
| Miscellaneous Accessories | Emergency |
| Available Product Colours | White |
| 100 | 100W nominal. 1530 × 360 × 93 mm, 11.5 kg (excludes bracketry). CE, RoHS. |
|---|---|
| 150 | 150W nominal. 1530 × 360 × 93 mm, 11.5 kg (excludes bracketry). CE, RoHS. |
| 200 | 200W nominal. 1530 × 360 × 93 mm, 11.5 kg (excludes bracketry). CE, RoHS. |
UGR varies with the light distribution. Contact the office for further details.
Electrical parameters are for D1 drivers unless otherwise stated. The fixture weight excludes bracketry; see the Packaging Weights & Dimensions data sheet for bracketry and accessory weights.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
Select a compatible driver for occupancy sensors with dimming.
Modifications which affect light output have separate photometric files identified with +(modification).
Alternative drivers may be available. Contact the office for further details, including driver parameters.
If the product is customised, the code is altered.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste