80
80° circular (H5V5)
Symmetric
Clear
Measured, SOM3-100-757-80
Hazardous Area · High Bay and Low Bay
Zone 2 ATEX Floodlights
Order code SOM3-100-757-120-V4-UB-GR-I1
13,600 lm
CRI>70, 5700K. 120° circular (H6V6) optic. GR Grey (RAL7040) - C5 rated.
No lumen is published for that combination.
Measured file SOM3-100-757-120: 14,062 lm at 98.9 W (142.2 lm/W).
100W nominal. 336 × 336 × 164 mm, 10.4 kg. CE, RoHS, ATEX.
The Somerville Series LED ATEX floodlights offer a versatile lighting solution for Zone 2 (zones 2 and 22) hazardous area applications.
Available in power options ranging from 80W to 150W, these floodlights use high-efficacy Luxeon 5050 LED chips and offer wide (120°) or medium (80°) beam distributions. This allows for precise illumination across various mounting heights while minimising energy consumption.
Each unit comes standard with an individually certified ATEX gland and blanking plug. Designed for flexibility, the fixtures also support wire-in/wire-out configurations and can be machined for a range of inlet thread sizes, making them suitable for both basic installations and projects requiring compliance with specific site standards.
Additional adaptability is provided through a variety of mounting options, including universal bracket, surface, pole, and recessed mount configurations.
| Series code | SOM3 |
|---|---|
| Nominal power | 80W to 150W |
| Efficacy | 136lm/W @ CRI>70, 5700K CCT |
| Lumen output | 10,880lm to 20,400lm |
| Lumen maintenance | L80B10 ≥67,029 hours @ 25°C ambient (TM21 reported), ≥86,468 hours (TM21 calculated) |
| Certification | CE, RoHS, ATEX |
| Warranty | 5 Years |
Sheet lumen at CRI>70, 5700K, with no modification: 80 10,880 lm, 100 13,600 lm, 120 16,320 lm, 150 20,400 lm. Another CRI, or a modification, still prints the order code and leaves the lumen blank. 8 measured files give 127.1 to 145 lm/W; the measured figure for the chosen optic shows under the code.
Questions for Adam list what the sheet and the measured files do not settle yet.
80° circular (H5V5)
Symmetric
Clear
Measured, SOM3-100-757-80
120° circular (H6V6)
Symmetric
Clear
Measured, SOM3-100-757-120
Polar: solid green C0–C180, dashed blue C90–C270, dotted amber the plane through the brightest direction when it lies between them; rings at 25% steps of the peak. Isolux: the footprint on the floor with the fitting aimed straight down, contours at 50%, 25% and 10% of the brightest point, grid in mounting heights (H). Both are drawn from the first measured file for that optic.
With a wattage range of 80W to 150W, the Somerville Series is designed to be a general purpose ATEX Rated (Zone 2) floodlight. Features include: Mounting: The Somerville line-up offers users 4 Installation options. The standard universal mounting bracket allows 360° rotation within cradle. Alternatives include a surface-mounting bracket, pole slip fitters for area lighting application, and pendant loops for ATEX high bay usage and reduced fitting variation across site. Heat Dissipation: The Somerville series has the wide ambient usage tolerance of -40° to 55°C. LED chips spacing and the driver being placed externally on the back of the light fitting provides excellent heat dissipation and lower junction temperatures resulting in a lumen maintenance of L70 ≥ 120,000 Hours. Environmental Protection: It offers IP66 protection by using aluminium body that comes with corrosion resistant paint finish - Salt spray testing reports available. Impact Resistance: Risk of early failure is mitigated by using a shock and vibration-resistant aluminium alloy housing capable of withstanding an impact of up to 10 Joules (IK10). A tempered glass lens provides impact resistance up to IK08. An optional stainless steel guard increases this to IK10.


These lights provide sufficient coverage for vehicle loading and unloading of Hazardous Substances while providing resistance against hazardous conditions.

Lighting for Distilleries must find a balance between style and function; lights must offer optimum performance in vapour-filled environments.

Lighting for grain processing and storage rooms must work in the presence of flammable dust, meeting regulations for hazardous areas and food production.

Oil rig lights need to perform in harsh environments where safety is paramount. We offer a variety of LED ATEX explosion-proof lighting for oil rigs.

Lux levels and hazardous area Zone 1 and Zone 2 lighting for tank farms. We have the product range and experience of lighting design needed for tank farms.

For oil refinery lighting and for the petro-chemical sector, Kellwood Lighting offer a range of marine grade LED ATEX / IECEx approved lighting products.
Showing 1-1 of 1
| Chip Brand, Model, & Size | Luxeon 5050 |
|---|---|
| Chip Efficacy @ CRI>70, 5700K CCT | 166 lm/W @ 160mA, Tj=25°C |
| Light Emmission | Direct |
| CCT | 5700K, (3000K, 4000K, 5000K optional) |
| CRI | ≥70Ra, (≥80Ra optional) |
| Diffusers | Clear |
| Symmetric Light Distribution | 120°, (80° optional) |
| System Operating Power | SOM3-80: 80W; SOM3-100: 100W; SOM3-120: 120W; SOM3-150: 150W |
|---|---|
| Input Voltage | 100-277VAC |
| Input Frequency | 50-60Hz |
| Inrush Current @100-277VAC | SOM3-80: 60A; SOM3-100: 60A; SOM3-120: 65A; SOM3-150: 65A |
| Power Factor | >0.98 |
| THD | <10% (100-277VAC) |
| Insulation Class | I |
| Surge Protection/Fusing | 5kV |
| IP Rating | IP66 |
|---|---|
| IK Rating | IK10 housing / IK08 front face, or IK10 / IK10 with the wire guard |
| Ambient Usage Tolerance | -40°C to 55°C |
| Marine Resistance Rating | C5 |
| Ambient Storage Tolerance | -40°C to 55°C |
| Ambient Humidity Tolerance | 0% to 90% RH |
| Product Dimensions: LxWxH (mm) | 336 x 336 x 164 |
|---|---|
| Qty of LED Chips | SOM3-80: 42; SOM3-100: 56; SOM3-120: 60; SOM3-150: 72 |
| Electrical Connection | Terminal block 1mm² to 4mm²; 0.7m 1mm² 3-core cable (1mm² to 2mm² if installed as wire-in-wire-out) |
| Wire-In-Wire-Out Installation | Yes |
| Inlet Thread | M20 (M20x1.5), M25 (M25x1.5), NPT3/4” |
| Gland Type | Brass with Nickel Plated Non-Armoured (Armoured optional) |
| Suitable Cable Size (ø) | M20 = 6.1-13.2mm, M25 = 9.5-15.9mm, NPT3/4” = 12.5-20.5mm |
| Fixture Weight | SOM3-80: 10.3kg; SOM3-100: 10.4kg; SOM3-120: 10.4kg; SOM3-150: 10.5kg (excludes bracketry) |
| Fixture Primary Material(s) | ADC12 Aluminium Alloy (1.5-3.5% Copper) and 316 Stainless Steel Fixings |
| Fixture Finish | Epoxy Powder Coated |
| Lens(es) Materials | Tempered Glass |
| Protection Method | Restricted breathing |
| Mounting Styles | Recessed Mount, Surface Mount Bracket, Universal Bracket, Slip Fit |
|---|---|
| Available Product Colours | Grey (RAL7040) |
| Division | Zone 2 & 22 |
|---|---|
| Product marking | II 3 GD, Ex nR IIC T* or T* Gc, Ex tc IIIC T* or T* Dc |
| Temperature class, -40° to 55°C (Ta) | 80W and 100W: gas T6, dust T85°C; 120W and 150W: gas T5, dust T95°C |
| Temperature class, -40° to 65°C (Ta) | 80W and 100W: gas T5, dust T95°C; 120W and 150W: not rated |
| Certificate number | ATEX: TUV 15 ATEX 7672 X |
| 80 | 80W nominal. 336 × 336 × 164 mm, 10.3 kg. CE, RoHS, ATEX. |
|---|---|
| 100 | 100W nominal. 336 × 336 × 164 mm, 10.4 kg. CE, RoHS, ATEX. |
| 120 | 120W nominal. 336 × 336 × 164 mm, 10.4 kg. CE, RoHS, ATEX. |
| 150 | 150W nominal. 336 × 336 × 164 mm, 10.5 kg. CE, RoHS, ATEX. |
Details are for the standard non-dimming driver. Fixture weights exclude bracketry.
IK rating format is housing / front face; IK10 front face when fitted with the wire guard.
Wire-in-wire-out products are supplied with one non-armoured ATEX certified gland and one ATEX certified blanking plug. Armoured cable glands are an option; contact Kellwood.
The stated cable size applies to the standard gland; armoured cable may vary.
Hazardous area certified product modifications are typically limited to bracketry, to keep certification. Products are supplied with OEM nameplates, codes and documentation corresponding to the certification.
If more than one modification is required, separate each modification with a hyphen at the end of the product code.
Modifications which affect light output have separate photometric files identified with +(modification).
Alternative drivers may be available. Contact the office for further details.
If the product is customised, the code is altered.
Contact the office for further information on driver parameters.
The Best Place to Install LED Drivers in Outdoor Sports Lighting ProjectsSports Lighting · Michael Boyom · 28th April, 2026
Should You Choose an ISO9001 Lighting Supplier?Business News · Adam Maitland · 18th April, 2026
Red-White LED Lighting for FETF 300 GrantsIndustrial Lighting · Adam Maitland · 24th March, 2026Our lights are used by
I am delighted to have used Kellwood...
P. Nisbet, Wabtec Corporationa project that was well planned and promptly accomplished
E. McHugh, LoganairWhere others let us down, Kellwood did not
W. Coley, Barking Abbey School...my client is over the moon with the end results
A. Fraser, MacLean ElectricalI'd certainly recommend them
V. Richardson, Stolle EuropeI'm more than pleased with the guys. I'd recommend them to anyone
G. Gray, Logoplaste